Drive the OnAirScreen ON AIR LED from PlayoutONE

Aiir PlayoutONE can turn OnAirScreen LED1 (factory label ON AIR) when Data Controller sees a mixer GPI (Axia, Wheatstone, serial) and runs RUNAPP with oas_send.

This is not the current-title howto. Titles: Show the current PlayoutONE title on OnAirScreen.

API reference: OnAirScreen API / UDP / HTTP / MQTT
Mixer GPI on a Raspberry Pi (no playout in between): User Manual (GPIO)
Aiir: Data Controller, Axia GPI, Commands (RUNAPP, IPCOMMAND)

Two different “on air” signals

Signal What it is Use for LED1?
Data Controller GPI (Axia pin, Wheatstone LIO, COM closure) Desk tally into PlayoutONE Yes — this is the studio lamp
ONAIR / OFFAIR / ONAIR CHANGE Which PC is the on-air machine No — studio take-over, not mic live

ONAIR CHANGE is the wrong event for a lamp.

What OnAirScreen expects

Channel Target (default) Example
HTTP Port 8010 http://OAS-IP:8010/?cmd=LED1:ON
UDP Port 3310 LED1:ON

Same pattern for off: LED1:OFF. OnAirScreen has no TCP command port — do not point IPCOMMAND at UDP 3310.

On Windows test with oas_send.exe from the OnAirScreen license:

oas_send.exe --ip 192.168.23.5 "LED1:ON"
oas_send.exe --ip 192.168.23.5 "LED1:OFF"

Use oas_send-noconsole.exe from the same license in RUNAPP so no console flashes on air. If OnAirScreen runs on the same PC, use 127.0.0.1.

1. Data Controller running; mixer integration on (e.g. Settings → Integrations → Axia node). What is Data Controller?

2. Two PlayoutONE Commands (Command Manager):

LED1 on (RUNAPP path, then > then arguments — RUNAPP):

RUNAPP C:\Path\To\oas_send-noconsole.exe>--ip 192.168.23.5 "LED1:ON"

LED1 off: same with LED1:OFF. Adjust the path to where the OnAirScreen tools sit.

3. Data Controller command matrix: incoming GPI (Axia pin ON/OFF, Wheatstone SLIO, serial string) to those two commands. Pin ON / high → LED1 on; pin OFF / low → LED1 off. You can keep an existing “Play Next” mapping and add a second command for the lamp.

Axia GPIO capture: Connecting to Axia nodes.

Firewall: the PlayoutONE PC must reach OnAirScreen TCP 8010 (oas_send uses HTTP) or UDP 3310.

Option B — HTTP without oas_send

If you would rather hit the API from a one-liner:

RUNAPP C:\Windows\System32\curl.exe>-s "http://192.168.23.5:8010/?cmd=LED1:ON"

OnAirScreen still needs GET. There is no PlayoutONE “HTTP GET metadata output” for GPI — Monitor metadata is titles only (title howto).

Notes

Other LED howtos

mAirList · ProppFrexx · Myriad Playout · PlayoutONE · RØDECaster Pro II (MIDI)

Titles: mAirList · RadioBOSS · RadioDJ · PlayoutONE · StationPlaylist · ProppFrexx · Myriad Playout · RCS Zetta